H401-OLYMPUS-IX-SUSP-T-PAD - FULL STAGE HEATER
The Stage Heater covers the entire GX-SFR and IX2-SFR Olympus stages and provides a flat, smooth surface at controlled temperature. It clamps on the stage and it is fixed in place by set crews positioned on the vertical sides of the plate. The Stage Heater leaves the observation hole open.
It is possible and recommendable to use the Stage Heater in combination with Glass Heated Insert. In this configuration, the H401-T-CONTROLLER uses one channel to control the metal PAD and the other channel to control the Glass Insert. Models available for Nikon and Olympus stages.
Recommended controller: H401-T-CONTROLLER.
Features
- Clamps on the GX-SFR and IX2-SFR Olympus stages and creates a flat surface at constant T
- Temperature range: from ambient to 45°C
- Accuracy: ±0.3°C
- 4.3'' touch screen controller
- On-board Data logging and download routines to USB drive
- Compatible with Glass Plates
- Easy to fix on stage
H401-T-CONTROLLER
T - range: from ambient to 60°C
4.3'' touch screen interface
External T - sensor (included)
On-board Data logging and download routines to USB drive
One controllers can control independently up to two devices
Self calibration routines allow to improve temperature accuracy
Data Logging
On-Board Data Logging - stored in local memory
Download to USB
H401-T-CONTROLLER
2-Channel Temperature Controller with 4.3'' touch screen interface compatible with all H401 heating devices. One controller can control independently up to two items.
External temperature sensor (included) and self calibration routines allows easy calibration of the heating devices for the highest accuracy on sample temperature.
On board data logging and download procedures to USB drives allow to record temperature as a function of time and to log calibration events and alarms.
The controller is equipped with password protected routines to re-calibrate the sensors against certified thermometers.
Features
- T - range: from ambient to 60°C
- T - accuracy on specimen: ± 0.3°C
- 4.3'' touch screen interface
- External T - sensor (included)
- On-board Data logging and download routines to USB drive
- On-board logging of calibration and alarm events
- Alarm buzzer and External Alarm Connector
- One controllers can control independently up to two devices
- Self calibration routines allow to improve temperature accuracy
- Password protected procedure for periodic calibration against certified thermometer
Touch Pad Interface
Beautifully designed, simple to use and very compact.
T - range: from ambient to 60°C
4.3'' touch screen interface
Beautifully designed, simple to use and very compact.
External T - sensor (included)
On-board Data logging and download routines to USB drive
One controllers can control independently up to two devices
Self calibration routines allow to improve temperature accuracy
Take advantage of the dual channel option
One channel controls the metal T-Pad.
The other channel controls the Glass Plate.
Data Logging
On-Board Data Logging - stored in local memory
A simple procedure allows to download data to USB.